Device records (parquet)

Audience: analysts who need the raw native adapter records (not the binding-projected channel samples); plugin authors deciding what shape a new adapter should emit. Scope: the device_records/<adapter>.parquet files — the four record shapes, per-adapter schemas, the schema-drift contract, and the link to scalars.parquet.

The channel-binding system in hardware.toml decides which adapter-emitted fields get projected into scalars.parquet as normalized channel samples. That projection is intentional — it's what gives every plot, alarm, and downstream analyzer a single canonical long table to read from. But it's also lossy by design: any library-native field the binding did not promote is gone from scalars.parquet. The device_records/ directory is the unprocessed safety net. Every row an adapter emitted, in its native shape, lands here in one parquet file per adapter family. A future analyst can re-derive a channel the original binding never knew to promote without having to re-run the rig.


The four record shapes

Every SourceRecord carries a shape tag drawn from the closed set RecordShape. The tag mirrors the library's natural row/block layout:

Shape When Layout
wide_row Most multi-channel adapters (Alicat, NI-DAQ polled, NI-DAQ block metadata) One row per emission, columns = readings (Mass_Flow, Abs_Press, …)
long_row Watlow (one parameter at a time over Modbus) Rows of (device, parameter, instance, value)
single_value_row Sartorius balance One value per record — the mass reading
block Reserved for kHz NI-DAQ acquisition via TDMS sidecar Metadata record; bulk samples live in a sidecar (not currently emitted in tree)

The shape tag for each adapter family is mirrored into the bundle manifest's data_shape.device_records[].layout field by finalize.py, so a reader can decide how to interpret each file without opening it first. The known mapping is defined in _KNOWN_LAYOUTS and lives in lockstep with the adapter source.


The device_records/ directory

Each adapter family writes exactly one parquet file under device_records/, named after the adapter id (DEVICE_RECORDS_DIRNAME = "device_records"):

runs/<run_id>/device_records/
├── alicat.parquet           # wide_row
├── watlow.parquet           # long_row
├── sartorius.parquet        # single_value_row
├── nidaq_polled.parquet     # wide_row
└── nidaq_block.parquet      # wide_row block-metadata records (when block mode is used)

Per-family multiplexing: if two Alicats are configured in the same run, both contribute rows to the same alicat.parquet. The device column (Alicat-adapter-assigned name, matching ChannelSpec.source.device) disambiguates them. This is the DeviceRecordsSink routing one _PerFamilyWriter per record.adapter, regardless of how many physical devices that family covers.


Per-adapter shape

Alicat — wide_row

Each alicatlib.Sample is one DataFrame row per poll. The emit site is in alicat.py: the adapter calls alicatlib.sample_to_row(sample) (the library's own canonical serializer) so the row schema is identical to what an offline alicatlib recorder would produce. That parity guarantee is what lets sim and real bundles flow through the same downstream tooling without branching.

Columns (firmware-dependent measurement fields; the canonical t_mono_ns, t_utc, and record_id headers are prepended by the sink):

record_id, t_mono_ns, t_utc,
device, unit_id,
Mass_Flow, Abs_Press, Mass_Flow_Setpt, Mix_Gas, status,
requested_at, received_at, midpoint_at, monotonic_ns, latency_s

Field names use alicatlib's underscored canonical form (Mass_Flow, not "Mass Flow"). Which measurement columns appear depends on the device's firmware — a pressure controller and a mass-flow controller will produce different column sets, but each is stable for the life of a run.

Watlow — long_row

Watlow speaks Modbus, reading one parameter at a time. A single tick of the worker therefore produces several records, each carrying a single (parameter, instance) reading. The adapter (watlow.py) emits one SourceRecord per parameter via watlowlib.sample_to_row(sample):

record_id, t_mono_ns, t_utc,
device, address, protocol,
parameter, parameter_id, instance, value, unit,
requested_at, received_at, latency_s

The parameter column holds the readable parameter name (process_value, setpoint, …); instance is the loop index (1-based) for multi-loop controllers. The metadata field also carries tick_first so the conductor can collapse a parameter fanout back into a single observation per acquisition tick when reporting the operator-facing poll rate.

Sartorius — single_value_row

The balance reports a single mass reading per poll. The adapter (sartorius.py) emits one record per reading through sartoriuslib.sample_to_row:

record_id, t_mono_ns, t_utc,
device,
value, unit, sign, stable, overload, underload, decimals, sequence,
requested_at, received_at, latency_s

(Column set inferred from the sartoriuslib.Reading fields constructed in sartorius_sim.py; the real adapter uses the same library serializer, but the exact final column set is whatever sartoriuslib.sinks.sample_to_row produces.) The stable, overload, and underload boolean flags are what the safety layer reads to gate ignition-time procedure steps; they are also surfaced on the derived channel sample's status ("ok" / "settling" / "overload").

NI-DAQ polled — wide_row

Polled mode (timing is None or timing.mode == "on_demand") drives nidaqlib.streaming.record_polled and emits one wide row per read via nidaqlib.reading_to_row — see nidaq.py around line 704:

record_id, t_mono_ns, t_utc,
device, task,
<channel_1>, <channel_2>, …, <channel_N>,
requested_at, received_at, latency_s

One column per declared NI channel. Suitable for the common 3–60 Hz scalar TC / analog-in case.


NI-DAQ block mode and the block shape

This is the corner that surprises people, so it gets its own section.

The block shape exists in the type system but is not emitted by any in-tree adapter today. The RecordShape literal includes "block", the DeviceRecordsSink knows how to count and skip those records (skipped_blocks tracks them, the bulk-sample landing path was deferred to a TDMS sidecar that hasn't been implemented yet), and the manifest's _KNOWN_LAYOUTS reserves the "block" layout tag for nidaq_block. But what the NI-DAQ block-mode adapter actually emits is shape="wide_row" — one metadata record per DaqBlock (see nidaq.py:_record_for_block around line 755):

record_id, t_mono_ns, t_utc,
block_index, first_sample_index, samples_per_channel,
sample_rate_hz, channels, task_started_at,
read_started_at, read_finished_at, elapsed_s

The per-sample measurements are not written into device_records/nidaq_block.parquet. Instead, each block is unrolled into samples_per_channel × bound_channels ChannelSamples and routed through scalars.parquet, with per-sample timestamps reconstructed as task_started_at + (first_sample_index + k) / sample_rate_hz. The device_records/nidaq_block.parquet file is metadata-only — useful for joining a block id back to its source-side timing, but not where the kHz analog values live.

Note for analysts. If you want NI-DAQ hardware-clocked samples, read scalars.parquet filtered to the bound channels. The device_records/nidaq_block.parquet rows tell you which block a sample came from, not what the values were. Despite this on-disk reality, the manifest's data_shape.device_records entry for nidaq_block still publishes layout: "block" — a forward-compatible label, not a current-state description.

The fan-out is gated at adapter open by max_samples_per_block_unroll (default 10 000). Configurations that would exceed it fail to open with a pointer to the (still-deferred) rectangular sidecar path.


Schema-drift contract

Within a single run, an adapter's emitted column set MUST be stable. The sink's _PerFamilyWriter infers the schema from the first batch of rows it flushes and then locks it. Every subsequent row is cast against the locked schema; rows that introduce columns the locked schema doesn't know about raise SchemaDriftError, and the run will fail (the conductor surfaces this as a crash). The same error fires if the per-adapter shape tag changes mid-run — e.g. a Watlow long_row adapter that suddenly tries to emit a wide_row.

The rationale is simple: parquet rewrite at finalize needs a stable schema across the full row stream. There is no "schema-per-row-group" escape hatch — a single locked schema covers every row in the file. Strict failure beats a corrupted device-records file that downstream tooling can't open.

Practical implication for plugin authors. Emit a stable column set from the very first record onwards. If a measurement is sometimes absent (e.g. a gas-mix column that's only present when the controller is in mix mode), emit it as None rather than omitting the key. The schema inference at first flush treats unseen keys exactly like seen-as-None keys (both become nullable columns), so explicit nulls round-trip cleanly. Late-arriving keys do not.


Linking records back to channel samples

Every ChannelSample carries a source_record_id back-pointer to the SourceRecord.record_id that produced it (and a source_field naming the specific library-native field the binding projected). That's the join key for round-tripping from scalars.parquet back into device_records/<adapter>.parquet. Record ids are constructed per-adapter, per-device, per-sequence (make_record_id(adapter_id, device_name, seq)) and are stable for the life of the run.

A typical polars round-trip — "find the raw Alicat row behind this temperature sample":

import polars as pl

samples = pl.read_parquet("runs/<run_id>/scalars.parquet")
alicat  = pl.read_parquet("runs/<run_id>/device_records/alicat.parquet")

joined = (
    samples.filter(pl.col("channel") == "mfc_n2_flow")
           .join(alicat, left_on="source_record_id", right_on="record_id", how="left")
)

For Watlow's long_row shape, the same join works — a single channel sample joins back to one Watlow row, identified by the (parameter, instance) columns alongside the bound value.


When to read records vs. channel samples

Reach for scalars.parquet when… Reach for device_records/<adapter>.parquet when…
The binding promotes the field you care about The binding didn't promote a field you now want
You want canonical units (degC, sccm, Pa) You want raw pre-calibration values in their library-native units
You want cross-adapter alignment on a single timeline You're auditing exactly what an adapter actually emitted
You're plotting, alarming, or running downstream analysis You're debugging a binding or chasing a calibration mismatch

scalars.parquet is the right answer for 90% of analysis. device_records/ is the right answer when scalars.parquet doesn't carry the column you need — and that's the whole reason the records files exist.


Implementation notes for contributors

A few details about the sink that aren't obvious from the public API:

  • One adapter family, one parquet file. Multiple physical devices of the same family multiplex via the device column. The sink keys on SourceRecord.adapter (the adapter-id string), not on device — so two Alicats produce one file, but Alicat plus Watlow produce two files.
  • Type inference locks after the first flush per family. The sink learns the schema from the first buffered batch and rejects drift thereafter. Columns whose only observed value is None are typed as nullable string — the safest fallback that round-trips both subsequent text and numerics (the latter via stringification rather than silent truncation).
  • Header columns are added by the sink, not the adapter. record_id, t_mono_ns, and t_utc are prepended by _record_to_row and shadow any same-named keys in record.row. The library-native column with the same name (if any) is preserved alongside under its library name, but the canonical join column is the sink's.
  • block-shape records are skipped, not erroneous. The sink counts them in skipped_blocks per adapter and writes nothing to disk — the TDMS sidecar landing path is deferred work. Today no in-tree adapter emits shape="block", so this skip path is effectively dormant.
  • Block-record invariants are enforced by SourceRecord. A block record must have empty row and a non-None block_ref; a non-block record must have block_ref=None. The pydantic model_validator rejects the violation at construction time, so a malformed record never reaches the sink.
  • Two-stage finalize. While the run is live, the sink writes Arrow IPC streams to <adapter>.in-flight.arrows. At finalize, those are rewritten to <adapter>.parquet with large row groups, sorted by t_mono_ns, zstd-compressed (see Integrity and sealing for the rewrite-then-seal protocol).

See also: Channel samples (parquet) · Channel bindings · Devices overview · Reading a bundle · Integrity and sealing