Modbus RTU mapping

watlowlib speaks Modbus RTU through the in-house anymodbus package. Modbus variants emit a typed ModbusOp (function code + address + register words), not raw wire bytes — anymodbus builds the PDU and CRC. This page documents how Watlow parameter ids map to Modbus register addresses, the encoding rules, and the Watlow-specific quirks that the codec abstracts away.

For framing, see the Standard Bus protocol reference for the alternate wire (Modbus RTU itself is a fully published protocol).

When to use Modbus over Standard Bus

Modbus RTU is opt-in: the SKU must include the comms stack (PM position-8 ∈ 1, 2, B, D, E, F) and the device must be flipped to Modbus mode at parameter 17009. Standard Bus is the factory default and is always available — see Troubleshooting. Reasons you might pick Modbus:

  • You're integrating with a PLC or HMI that already speaks Modbus.
  • You want a published wire spec rather than a partially-RE'd one.
  • Your bus is shared with non-Watlow Modbus devices.

The Controller facade is identical either way — a parameter read against setpoint returns the same Reading whether the session opened in Std Bus or Modbus.

Address mapping

Each ParameterSpec carries two Modbus addresses:

Field Notes
relative_addr Per-block offset from the EZ-ZONE PM register list (e.g. process value = 360 = 0x168).
absolute_addr Full register address on the wire.
register_count Number of 16-bit registers the parameter occupies (1 for u16, 2 for float / s32 / u32, more for short strings).
word_order HIGH_LOW (default) or LOW_HIGH for multi-register values.

The Std Bus selector (cls, member, default_instance, max_instance) and the Modbus selector are both populated for every registry row. The session uses whichever matches the active protocol.

For multi-loop SKUs, each loop occupies the next register block — the spec's relative_addr is loop 1; loop 2 reads from relative_addr + loop_block_size. The codec handles the offset; callers pass instance=N and the variant computes the right address.

Function-code dispatch

Watlow uses the standard Modbus function codes:

Function code Name Used for
0x03 Read Holding Registers reading any parameter
0x06 Write Single Register u16 / single-register writes
0x10 Write Multiple Registers float / s32 / u32 / multi-register writes

anymodbus selects the right code from the parameter's register_count and the operation. Watlow does not use coil or input-register spaces.

Data type encodings

DataType Registers Encoding
FLOAT 2 IEEE 754 32-bit, default HIGH_LOW word order. EZ-ZONE PM has historically shipped both orderings depending on configuration; the registry's word_order field overrides.
S32 2 Signed two's-complement 32-bit, HIGH_LOW.
U32 2 Unsigned 32-bit, HIGH_LOW.
U16 1 Unsigned 16-bit. Most enumerations live here.
U8 1 Unsigned 8-bit packed in the low byte; high byte zero.
STRING N ASCII, two characters per register; null-padded.
PACKED 1 Enumeration code (u16 wire encoding).

The encoding lookup is centralised in protocol/modbus/tables.py behind encoding_for(data_type).

Word order

Watlow EZ-ZONE PM exposes a Data Map parameter (id 16562, the COMM_DATA_MAP register) that toggles word order between high-low and low-low formats. Different controllers and firmwares default differently. Symptom of a mismatch: read PV looks like 1.5e-12 or 1e34 instead of a reasonable temperature.

The library's defaults match the most common EZ-ZONE PM setting; if your controller is configured for the other order, override at the registry level (see ParameterSpec.word_order) or write COMM_DATA_MAP to match.

Exception codes

Modbus exception responses map to the typed error hierarchy:

Exception code Mnemonic Typed error
01 Illegal Function WatlowModbusIllegalFunctionError (also a WatlowProtocolUnsupportedError)
02 Illegal Data Address WatlowModbusIllegalDataAddressError (also a WatlowProtocolUnsupportedError)
03 Illegal Data Value WatlowModbusIllegalDataValueError
04 Slave Device Failure WatlowModbusSlaveFailureError
(timeout) no reply within timeout WatlowModbusTimeoutError (also a WatlowTimeoutError)

Codes 01 and 02 flip the per-session availability cache to UNSUPPORTED for the offending parameter — the same shape as the Std Bus "no such object/attribute/instance" responses. Code 03 is treated as a transient validation error and does not poison the cache. See Design §5b for the availability transition table.

Lock model

ModbusProtocolClient holds one anyio.Lock per port. Multiple controllers on the same RS-485 segment share the lock and serialise their I/O. The WatlowManager enforces one protocol per port — mixing Std Bus and Modbus on the same RS-485 segment raises WatlowConfigurationError at add() time.