anymodbus — Design Plan

Status: Draft v0.1 (post spec audit) Target Python: 3.13+ Target AnyIO: ≥ 4.13 Transport floor: anyserial >= 0.1.1 (also accepts any anyio.abc.ByteStream) License: MIT Author: Grayson Bellamy Last updated: 2026-04-25


1. Mission

A small, async-native, half-duplex-correct Modbus RTU client for Python, built on anyserial and AnyIO. It is intentionally protocol-only — no servers, no device-specific knowledge. It serves as the substrate for downstream device libraries that wrap a single vendor's register map and conventions on top.

The niche it fills: nothing in the ecosystem today is AnyIO-native, half-duplex-correct on a shared bus, and length-aware in its rx framer. anymodbus is.

2. Goals / Non-goals

Goals

  1. RTU client over any AnyIO ByteStream (concrete default: anyserial.SerialPort).
  2. Half-duplex single-master correctness — one outstanding transaction on the bus, period.
  3. Length-aware frame reader with timing-gap fallback only for unknown function codes.
  4. Honest 3.5-character pre-tx idle gap (tx-side, not relying on rx timing).
  5. Pure-function PDU codecs (encode/decode separated from I/O), property-tested.
  6. Per-slave handle (Slave(bus, address)) for ergonomic multi-drop access.
  7. Exception hierarchy that multi-inherits from stdlib + AnyIO bases (matches anyserial's idiom) and maps Modbus exception codes 1–11 to specific subclasses.
  8. Explicit word/byte-order enums for 32-bit values, with the most-common HIGH_LOW default (struct.pack(">f", ...) equivalent) and LOW_HIGH opt-in. (Word order is not spec-defined; only intra-register byte order is. See §11.)
  9. Sync wrapper with the same shared-portal pattern as anyserial.sync.
  10. anymodbus.testing exposing a MockSlave register bank + client_slave_pair() helper + FaultPlan.
  11. Capability model (SUPPORTED/UNSUPPORTED/UNKNOWN) for function codes, populated from probe results.
  12. mypy --strict + pyright --strict clean, full PEP 561.

Non-goals (v1.x)

  • Modbus servers (slave-side). Out of scope.
  • Modbus ASCII transport.
  • Modbus TCP / RTU-over-TCP. (Architectural seam preserved — re-add later as anymodbus.tcp without breaking the Bus API.)
  • File-record FCs (0x14/0x15) — defer to v0.3+ unless a user asks.
  • Serial-line-only diagnostic FCs: 0x07 Read Exception Status, 0x08 Diagnostics, 0x0B Get Comm Event Counter, 0x0C Get Comm Event Log, 0x11 Report Server ID, 0x18 Read FIFO Queue. Out of scope for v0.1; add per user demand. The framer recognizes them as known-but-unsupported and raises ModbusUnsupportedFunctionError rather than mis-framing on the wire. Special case to keep on the radar when these are added: FC 0x08 sub-function 0x04 (Force Listen Only Mode) returns no response — must be handled like a broadcast.
  • Encapsulated Interface Transport (FC 0x2B). MEI Type 0x0E (Read Device Identification) is planned for v0.2; MEI Type 0x0D (CANopen General Reference) is out of scope.
  • Built-in device drivers beyond a tiny examples/ directory. Vendor-specific register maps and quirks live in their own downstream packages.

3. Architecture overview

Two crisp layers: transport-agnostic codec (pure functions, easy to test) and bus client (owns the lock, timing, framing, and stream).

┌───────────────────────────────────────────────┐
│   anymodbus.Bus(stream, *, options)           │  ← single-master, lock-protected
│   ├─ anyio.Lock + tx-gap timer                │
│   ├─ Framer.read_response(stream, expect_fc)  │  ← length-aware
│   └─ Codec (pure)                             │  ← encode/decode PDU
└───────────────────────────────────────────────┘
        ▲                            ▲
        │                            │
   anyserial.SerialPort        any anyio.ByteStream
   (RTU on real hardware)      (test pair, future TCP, ...)

Key invariant: the Bus holds an anyio.Lock. Concurrent await slave.read(...) calls from any task graph serialize through it — at most one outstanding transaction on the wire at a time, by construction.

4. Module layout (src-layout, mirrors anyserial)

src/anymodbus/
├── __init__.py            # Public re-exports + __version__
├── _version.py            # hatch-vcs generated
├── py.typed
├── _types.py              # FunctionCode, ExceptionCode, WordOrder, ByteOrder enums + small dataclasses
├── exceptions.py          # ModbusError tree + code_to_exception translator
├── capabilities.py        # ModbusCapabilities + ModbusStreamAttribute
├── config.py              # BusConfig, RetryPolicy, TimingConfig (frozen dataclasses)
├── crc.py                 # crc16_modbus(data) — 256-entry table-precomputed
├── pdu.py                 # PDU encode/decode pure functions
├── framer.py              # Length-aware ADU reader + ADU writer; uses crc + pdu
├── bus.py                 # Bus class — owns stream, lock, transactions
├── slave.py               # Slave handle bound to (bus, address); high-level methods
├── decoders.py            # int16/32/64 + float32/64 + string helpers, plus type-dispatched decode/encode
├── stream.py              # open_modbus_rtu(path, ...) convenience opener
├── sync.py                # Blocking wrappers; reuses anyserial portal hook
├── testing.py             # MockSlave, client_slave_pair, FaultPlan re-export
└── _mock/                 # Private: mock slave register bank, fault injection
    ├── __init__.py
    ├── slave.py
    ├── pair.py
    └── faults.py

Naming: Modbus* prefix on every public class; no Master/Slave ambiguity at the public surface — Bus and Slave are the user-facing nouns, and the Slave name is correct because the device is the slave (RTU vocabulary).

5. Public API sketch

5.1 Opening a bus

from anymodbus import Bus, BusConfig, RetryPolicy, open_modbus_rtu

# Convenience opener: opens the serial port and wraps in a Bus.
# baudrate and parity are required — Modbus RTU defaults vary too widely
# for any portable default to be safe. Consult your device's manual.
bus = await open_modbus_rtu(
    "/dev/ttyUSB0",
    baudrate=19_200,
    parity="even",
    config=BusConfig(
        request_timeout=3.0,                    # default
        retries=RetryPolicy(retries=1),         # default
        # timing.inter_frame_idle defaults to "auto" — computes 3.5 char-times from baud
    ),
)

# Or wrap an existing stream (e.g., test pair, future TCP):
from anyserial import open_serial_port, SerialConfig, Parity
port = await open_serial_port(
    "/dev/ttyUSB0",
    SerialConfig(baudrate=19_200, parity=Parity.EVEN),
)
bus = Bus(port, config=BusConfig())

5.2 Per-slave handle

slave = bus.slave(address=1)            # Slave handle is cheap, no I/O.

# Standard FCs:
coils = await slave.read_coils(0, count=8)                      # FC 0x01
disc  = await slave.read_discrete_inputs(0, count=16)           # FC 0x02
regs  = await slave.read_holding_registers(0x0040, count=2)     # FC 0x03
ins   = await slave.read_input_registers(0, count=4)            # FC 0x04
await slave.write_coil(0, on=True)                              # FC 0x05
await slave.write_register(0x0080, value=2500)                  # FC 0x06
await slave.write_coils(0, [True, False, True, True])           # FC 0x0F
await slave.write_registers(0x0040, [0x977D, 0x429C])           # FC 0x10

# v0.2:
await slave.mask_write_register(addr, and_mask=..., or_mask=...) # FC 0x16
await slave.read_write_registers(read_addr, read_count,
                                 write_addr, write_values)       # FC 0x17

# Per-type helpers + dispatcher (in anymodbus.decoders, also exposed on Slave for the common cases):
hv = await slave.read_float(0x0040)                              # high_low default
lv = await slave.read_float(0x0044, word_order="low_high")
await slave.write_float(0x0040, 78.295, word_order="high_low")

Address validation. bus.slave(address) validates per serial §2.2:

  • 1..247 are unicast addresses. bus.slave(addr) returns a normal slave handle.
  • 0 is the broadcast address; not valid for bus.slave(). Calling bus.slave(0) raises ConfigurationError("Use Bus.broadcast_* methods for broadcasts; bus.slave() is unicast only"). Broadcasts go through dedicated Bus.broadcast_write_coil(...), Bus.broadcast_write_register(...), Bus.broadcast_write_coils(...), Bus.broadcast_write_registers(...) methods (see §6.6).
  • 248..255 are reserved by the spec; bus.slave(248) raises ConfigurationError("Slave address must be 1-247. Address 0 is broadcast (see Bus.broadcast_*); 248-255 are reserved by the spec.").

Mask Write semantics. mask_write_register applies, on the slave side, the formula from Modbus Application Protocol v1.1b3 §6.16:

Result = (Current AND and_mask) OR (or_mask AND NOT and_mask)

Practically: a 1-bit in and_mask preserves the corresponding bit of the current register; a 0-bit clears it. After that masking, a 1-bit in or_mask at a position where and_mask is 0 sets that bit. Common patterns:

Intent and_mask or_mask
Set bits 0xFFFF ANDed with positions you want preserved (i.e. ~bits_to_set) bits_to_set
Clear bits ~bits_to_clear 0x0000
Leave register unchanged 0xFFFF 0x0000

5.3 Cancellation / timeouts

Standard AnyIO scopes work, with no library-side timer:

with anyio.move_on_after(0.5):
    regs = await slave.read_holding_registers(0, count=2)

The request_timeout in BusConfig is the default per-call deadline that wraps each transaction. Outer cancel scopes still preempt.

5.4 Sync wrapper (mirrors anyserial.sync)

from anymodbus.sync import open_modbus_rtu

with open_modbus_rtu("/dev/ttyUSB0", baudrate=19200, parity="even") as bus:
    slave = bus.slave(1)
    regs = slave.read_holding_registers(0, count=4, timeout=1.0)

Reuses anyserial's process-wide BlockingPortalProvider — does not spawn a second event-loop thread. Document the integration; export configure_portal as a re-export of anyserial.sync.configure_portal for users who want to set the AnyIO backend.

6. RTU framing & timing — the technical heart

Source documents. Function codes, PDU layout, and exception semantics come from Modbus Application Protocol Specification v1.1b3 (mirrored at docs/modbusprotocolspecification.md). Wire-level framing (3.5/1.5 char-time gaps, CRC byte order, slave address range, broadcast rules, turnaround delay, RTU character format) comes from Modbus over Serial Line Specification and Implementation Guide v1.02 (mirrored at docs/modbusoverserial.md). Section references in this document are written as app §X.Y and serial §X.Y respectively to disambiguate.

6.1 Tx-side: enforced 3.5-char pre-tx gap

Bus._txn records _last_io_monotonic. Before each tx:

gap = self.timing.inter_frame_idle  # seconds
elapsed = anyio.current_time() - self._last_io_monotonic
if elapsed < gap:
    await anyio.sleep(gap - elapsed)

Per serial §2.5.1.1:

  • t3.5 (inter-frame idle) — at least 3.5 character times of silence between frames. Default inter_frame_idle = max(3.5 * 11 / baudrate, 0.00175). The 1.75 ms floor is the spec-recommended fixed value for baud > 19200, where the per-character interrupt load otherwise becomes prohibitive.
  • t1.5 (inter-character idle) — at most 1.5 character times of silence within a single frame. Exposed as inter_char_idle = max(1.5 * 11 / baudrate, 0.00075) (750 µs spec floor at baud > 19200). Used by the unknown-FC fallback gap-based reader (§6.3) and the unexpected-slave drain logic.

The 11 in both formulas is the on-wire bit count per character: 1 start + 8 data + (1 parity OR 1 extra stop) + 1 stop = 11 bits. This holds for compliant 8E1, 8O1, and 8N2 wire formats. 8N1 (10 bits/char) is non-compliant per spec but exists in the wild — we err on the safe (longer) side by always assuming 11 bits, so the gap is ~10% longer than the wire actually requires under 8N1, which is harmless.

Both timing knobs are configurable as floats or the sentinel "auto". "auto" recomputes from the stream's current baud (looked up via the SerialStreamAttribute.config typed attribute, with a fallback default if the stream isn't a serial port).

Broadcast turnaround delay. After sending a broadcast (slave address 0; see §6.6) the master holds the bus idle for timing.broadcast_turnaround seconds before releasing the lock — distinct from request_timeout (which only applies to unicast since broadcasts have no response) and from t3.5 (which is wire-level). Default 0.100 s; spec recommends 100–200 ms (serial §2.4.1: "Typically the Response time-out is from 1s to several seconds at 9600 bps; and the Turnaround delay is from 100 ms to 200 ms").

6.2 Tx: write & flush

  1. await stream.send(adu_bytes).
  2. If the stream is a SerialPort and BusConfig.drain_after_send=True (default), await port.drain() to ensure the kernel has handed off bytes — important for RS-485 RTS-toggle correctness even when the kernel handles RTS, and nearly free otherwise.

6.3 Rx: length-aware read state machine

The framer uses a per-FC response-length table as the single source of truth, kept in framer.py and asserted directly in unit tests against the spec:

# Bytes to read after the 2-byte (slave_addr + fc) header, EXCLUDING those 2.
# CRC (2 bytes) is included in each value.
_FIXED_TAIL: Final[Mapping[int, int]] = {
    # fc:  start_addr(2) + value-or-quantity(2) + crc(2)
    0x05: 6,
    0x06: 6,
    0x0F: 6,
    0x10: 6,
    # fc:  ref_addr(2) + and_mask(2) + or_mask(2) + crc(2)
    0x16: 8,
}

# FCs whose response carries a 1-byte byte_count immediately after the FC byte.
_BYTE_COUNT_1B: Final[frozenset[int]] = frozenset({0x01, 0x02, 0x03, 0x04, 0x17})

# FCs known to the spec but not implemented by this version. Recognized so
# the framer can fail with a precise error rather than mis-frame.
_KNOWN_UNSUPPORTED: Final[frozenset[int]] = frozenset({
    0x07,  # Read Exception Status (serial line only)
    0x08,  # Diagnostics
    0x0B,  # Get Comm Event Counter
    0x0C,  # Get Comm Event Log
    0x11,  # Report Server ID
    0x14,  # Read File Record
    0x15,  # Write File Record
    0x18,  # Read FIFO Queue (note: 2-byte byte_count when implemented)
    0x2B,  # Encapsulated Interface Transport (MEI 0x0E planned for v0.2)
})

State machine:

S0 (await response within deadline):
  while not deadline_expired:
      buf = await read_exact(stream, 2, deadline)   # slave-addr + fc

      if buf[0] != expected_slave_address:
          # serial §2.4.1: a reply addressed to a different slave does NOT
          # abort the transaction. Keep the deadline running and keep
          # listening. Drain the stray frame using a t1.5 idle gap, then loop.
          await read_until_idle(stream, gap=timing.inter_char_idle)
          log.info("Discarded stray frame from slave 0x%02x", buf[0])
          continue
      break
  else:
      raise FrameTimeoutError

  fc = buf[1]
  if fc == 0:
      # app §4.1: function code 0 is not valid.
      raise ProtocolError("Slave returned function code 0 (invalid)")

  if fc & 0x80:
      # Exception response: total ADU = 5 bytes (slave + fc + ec + crc16).
      remaining = await read_exact(stream, 3, deadline)
      verify_crc(buf + remaining)
      base_fc = fc & 0x7F
      if base_fc != expected_fc:
          raise UnexpectedResponseError(
              f"exception echoes fc 0x{base_fc:02x}, expected 0x{expected_fc:02x}"
          )
      raise code_to_exception(remaining[0])(code=remaining[0])

  if fc != expected_fc:
      raise UnexpectedResponseError(
          f"slave returned fc 0x{fc:02x}, expected 0x{expected_fc:02x}"
      )

  if fc in _BYTE_COUNT_1B:
      bc_byte = await read_exact(stream, 1, deadline)
      bc = bc_byte[0]
      # app §4.1: PDU max = 253 bytes (so a 1-byte-bc payload tops out at
      # fc(1) + bc(1) + 250 data + crc(2) = 254-byte PDU on the wire). Reject
      # early to defend against a malformed slave inducing oversized reads.
      if bc > 250:
          raise FrameError(f"byte_count={bc} exceeds spec max of 250")
      data_and_crc = await read_exact(stream, bc + 2, deadline)
      payload = bc_byte + data_and_crc
  elif fc in _FIXED_TAIL:
      payload = await read_exact(stream, _FIXED_TAIL[fc], deadline)
  elif fc in _KNOWN_UNSUPPORTED:
      raise ModbusUnsupportedFunctionError(
          f"FC 0x{fc:02x} is defined by the Modbus spec but not implemented "
          f"by this version of anymodbus"
      )
  else:
      # Truly unknown FC (user-defined ranges 65-72, 100-110, or vendor
      # private). Fall back to gap-based read; imprecise but the only
      # option without per-FC length knowledge.
      payload = await read_until_idle(stream, gap=timing.inter_char_idle)

  verify_crc(buf + payload)
  return decode_pdu(fc, payload)

Notable framer behaviors:

  • FC 0x16 (Mask Write Register) has its own length entry of 8 bytes, not 6. The response is addr(2) + AND(2) + OR(2) + crc(2) = 8 bytes after the 2-byte header (app §6.16). Grouping it with FC 0x05/0x06/0x0F/0x10 (which are 6 bytes) would mis-frame the next response on the bus.
  • Unexpected slave addresses do not abort. Per serial §2.4.1, a reply addressed to a different slave keeps the response timeout running and the master continues to wait. This implementation drains the stray frame using a t1.5 idle gap and loops within the same deadline.
  • PDU max sanity check. A malformed slave that returns byte_count = 0xFF would otherwise induce a ~257-byte read — the explicit bc > 250 guard surfaces that as FrameError immediately and avoids large speculative allocations.
  • FC 0 is rejected with ProtocolError, since app §4.1 declares "Function code 0 is not valid".
  • Known-but-unsupported FCs (Diagnostics family, FIFO, file record, MEI transport) raise ModbusUnsupportedFunctionError instead of falling into the generic gap-based fallback. This stops a slave that supports more than we do from corrupting the stream just because we didn't know how to length-bound its response.
  • Exception responses are CRC-verified before raising. A bad CRC on an exception ADU surfaces as CRCError (retryable per RetryPolicy), not as the slave-reported exception code (which we'd then have no business trusting).

Why length-aware reads: they survive Linux/macOS scheduling jitter where response bytes arrive in 2–3 ms chunks. The 1.5-char gap fallback fires only for genuinely unknown FCs; standard FCs never exercise it. (pymodbus's rx framer uses the same length-aware approach via per-PDU calculateRtuFrameSize.)

read_exact is implemented over stream.receive with a buffered approach (bytearray accumulator, receive_into if the stream is an anyserial.SerialPort for zero-allocation reads).

6.4 CRC failure / resync

On CRC mismatch:

  1. await stream.reset_input_buffer() if the stream supports it (anyserial does).
  2. await anyio.sleep(timing.inter_frame_idle) — let the bus go idle for 3.5 char-times.
  3. Raise ModbusCRCError. The retry loop in Bus._txn decides whether to redrive the request.

6.5 Retry policy

@dataclass(frozen=True, slots=True, kw_only=True)
class RetryPolicy:
    retries: int = 1
    retry_on: frozenset[type[ModbusError]] = frozenset({CRCError, FrameTimeoutError})
    retry_idempotent_only: bool = True   # see is_idempotent_function
    backoff_base: float = 0.0            # extra wait beyond inter_frame_idle

retry_idempotent_only=True blocks silent re-writes — the failure mode being avoided is "the slave received and acted on the write but the response was lost in transit, so we retry and double-fire". Only function codes for which is_idempotent_function(fc) is True are retried under that policy — currently FC 1-4. FC 23 (Read/Write Multiple) is not automatically retried because of its write half; FC 22 (Mask Write) depends on the slave's current value and is also not auto-retried. Writes only retry when the caller explicitly opts in (retry_idempotent_only=False). Modbus exception responses (IllegalFunctionError etc.) are never retried — the slave told us no, retrying won't change that — so they are intentionally absent from the default retry_on set. pymodbus exposes a single retries: int applied to all FCs and does not make this distinction.

6.6 Broadcast handling

Per serial §2.1: "The broadcast requests are necessarily writing commands. All devices must accept the broadcast for writing function." Per serial §2.2, slave address 0 is reserved as the broadcast address.

Broadcasts have a different transaction shape from unicast — no reply, plus a turnaround delay — so they get their own typed API on Bus rather than overloading Slave:

class Bus:
    async def broadcast_write_coil(self, address: int, *, on: bool) -> None: ...        # FC 0x05
    async def broadcast_write_register(self, address: int, value: int) -> None: ...     # FC 0x06
    async def broadcast_write_coils(self, address: int, values: Sequence[bool]) -> None: ...    # FC 0x0F
    async def broadcast_write_registers(self, address: int, values: Sequence[int]) -> None: ... # FC 0x10

The Bus.broadcast_* methods are the only way to broadcast — there is no bus.slave(0) (it raises ConfigurationError; see §5.2). This deliberate asymmetry means callers can't accidentally broadcast a read FC, since the read FCs simply don't exist as broadcast_* variants.

Internally, each broadcast call routes through Bus._broadcast_txn(adu_bytes):

  1. Acquire the bus lock.
  2. Hold the t3.5 inter-frame gap (§6.1) just like unicast.
  3. await stream.send(adu_bytes) then drain().
  4. Skip the rx state machine entirely — broadcasts have no response.
  5. Hold the bus lock for an additional timing.broadcast_turnaround seconds (default 0.100 s; serial §2.4.1 recommends 100–200 ms) so every slave has time to process the write before the next transaction hits the bus.
  6. Release the lock. Return None.

The 3.5-char tx gap alone is not spec-compliant for broadcasts — the turnaround delay is the explicit "let slaves finish processing" window. Without it, a fast follow-up unicast can arrive while a slave is still busy applying the broadcast write.

A deferred case: when FC 0x08 (Diagnostics) lands, sub-function 0x01 (Restart Communications Option) is broadcast-eligible per app §6.8.1. It will surface as Bus.broadcast_restart_communications(...), routed through the same _broadcast_txn machinery.

7. Error model

Mirrors anyserial's multi-inheritance idiom. All inherit ModbusError plus a stdlib/AnyIO base.

Class Bases Trigger
ModbusError Exception Base
ConfigurationError ModbusError, ValueError Bad value passed to a config dataclass or constructor
ProtocolError ModbusError, ValueError Codec/framer rejected something well-formed
CRCError ProtocolError CRC mismatch
FrameError ProtocolError Truncated, junk between frames
FrameTimeoutError ModbusError, TimeoutError No response within deadline
ConnectionLostError ModbusError, anyio.BrokenResourceError Stream disconnected mid-txn
BusClosedError ModbusError, anyio.ClosedResourceError Bus closed
UnexpectedResponseError ProtocolError Slave addr or FC echoed doesn't match request
ModbusUnsupportedFunctionError ModbusError, NotImplementedError Caller asked for or framer received a known-but-not-implemented FC (see §6.3)

ConfigurationError is raised eagerly during BusConfig/RetryPolicy/TimingConfig/Slave construction; it never surfaces from a live transaction. Wire-level violations are ProtocolError. The two are deliberately distinct so callers can pre-validate their config without writing try/except around real I/O.

Modbus exception responses (function code with high bit set, body = an exception code byte) map to dedicated subclasses, all inheriting ModbusError (not ProtocolError — they're a slave-side semantic outcome, not a wire error). The codes covered by app §7 are:

Code Class
0x01 IllegalFunctionError
0x02 IllegalDataAddressError
0x03 IllegalDataValueError
0x04 SlaveDeviceFailureError
0x05 AcknowledgeError
0x06 SlaveDeviceBusyError
0x08 MemoryParityError
0x0A GatewayPathUnavailableError
0x0B GatewayTargetFailedToRespondError

Any code outside this set (notably 0x07, 0x09, and 0x0C–0xFF, which are unassigned in v1.1b3) raises ModbusUnknownExceptionError, which inherits from ModbusExceptionResponse so callers wanting "any slave-returned exception" can catch the base class. The raw byte is exposed on exception_code (inherited from the base):

class ModbusUnknownExceptionError(ModbusExceptionResponse):
    """Slave returned an exception code not defined by app §7."""
    # inherits exception_code: int from ModbusExceptionResponse

This is intentionally not a ProtocolError — the slave returned a well-formed exception ADU; we just don't have a named class for the code it chose. Callers who need to handle a specific legacy code (e.g. NAK on Modicon devices) can match on err.code == 0x07.

Legacy 0x07 (Negative Acknowledge). Pre-v1.1 Modicon controllers defined exception code 0x07 as "Negative Acknowledge". v1.1b3 §7 does not list 0x07; the NAK semantic was repositioned as a Diagnostics counter (FC 0x08 sub 0x10, app §6.8.1). We deliberately do not ship a NegativeAcknowledgeError class — anything a legacy device emits as 0x07 surfaces as ModbusUnknownExceptionError(code=0x07). Downstream device libraries that target old Modicon hardware can subclass and re-raise as needed.

code_to_exception(code: int) -> type[ModbusError] translator in exceptions.py, parallel to anyserial.errno_to_exception. Returns ModbusUnknownExceptionError for any unmapped code; never raises KeyError.

8. Capability model

class ModbusCapability(StrEnum):
    SUPPORTED = "supported"
    UNSUPPORTED = "unsupported"
    UNKNOWN = "unknown"

@dataclass(frozen=True, slots=True, kw_only=True)
class SlaveCapabilities:
    function_codes: Mapping[FunctionCode, ModbusCapability]   # Probed lazily.
    max_coils_per_read: int | None = None                     # Spec: 2000
    max_registers_per_read: int | None = None                 # Spec: 125

Slave.probe() runs FC 0x03 / 0x04 with count=1 against a few well-known offsets and maps the outcome:

  • success → SUPPORTED
  • IllegalFunctionError (exception code 0x01) → UNSUPPORTED (App Protocol §7 mandates this code for unimplemented FCs)
  • FrameTimeoutError / ConnectionLostErrorUNKNOWN (a silent slave is indistinguishable from a slave that drops unknown FCs without responding; do not downgrade silence to UNSUPPORTED)
  • IllegalDataAddressErrorSUPPORTED for the FC, but the probed address isn't valid; move the probe.

Cached on the slave handle. Optional — many users won't need it; downstream device libraries can skip probing because they already know what their device supports.

9. RS-485 strategy

Pass through to anyserial. BusConfig does not duplicate RS485Config knobs; users open the serial port with the RS-485 settings they want, then hand it to Bus. Document the canonical pattern:

from anyserial import open_serial_port, SerialConfig, RS485Config, Parity

port = await open_serial_port(
    "/dev/ttyUSB0",
    SerialConfig(
        baudrate=19_200,
        parity=Parity.EVEN,
        rs485=RS485Config(enabled=True, rts_on_send=True, rts_after_send=False),
    ),
)
bus = Bus(port)

Document a troubleshooting note for USB-RS485 adapters where the kernel can't auto-toggle RTS — point to anyserial's drain_exact + manual RTS pattern.

10. PDU codec — design notes

Each FC gets two pure functions:

def encode_read_holding_request(address: int, count: int) -> bytes: ...
def decode_read_holding_response(payload: bytes) -> tuple[int, ...]: ...
  • Bounds-checked. Addresses are always in [0, 0xFFFF] (app §4.4: "In a MODBUS PDU each data is addressed from 0 to 65535"). Per-FC quantity limits come straight from the spec:
FC Quantity range Spec
0x01 Read Coils 1 – 2000 (0x7D0) app §6.1
0x02 Read Discrete Inputs 1 – 2000 (0x7D0) app §6.2
0x03 Read Holding Registers 1 – 125 (0x7D) app §6.3
0x04 Read Input Registers 1 – 125 (0x7D) app §6.4
0x0F Write Multiple Coils 1 – 1968 (0x07B0) app §6.11
0x10 Write Multiple Registers 1 – 123 (0x7B) app §6.12
0x17 Read/Write Multiple Registers read 1 – 125, write 1 – 121 (0x79) app §6.17

Violations raise ValueError. Each encode_* enforces its own bounds; decode_* does not re-check (the framer has already accepted the byte_count).

  • FC 0x05 Write Single Coil — wire value. Per app §6.5, the value field on the wire must be exactly 0xFF00 (ON) or 0x0000 (OFF); any other value is a protocol violation. The high-level API takes on: bool and the encoder produces the correct word. The decoder of the echo response asserts the value is one of these two — otherwise ProtocolError.

  • Function code 0 is invalid. app §4.1: "Function code '0' is not valid." The FunctionCode enum does not include 0, so encoding is naturally protected; the framer rejects FC 0 in incoming responses with ProtocolError (see §6.3).

  • Strict types: registers are tuple[int, ...] (immutable), coils are tuple[bool, ...], write echoes return int start-address + int count.

  • Property-tested with hypothesis: roundtrip decode(encode(x)) == x for all valid inputs; encode raises on invalid; decode rejects truncated/oversized payloads.

CRC is its own module (crc.py) — single function, 256-entry precomputed table, hot-path-friendly. crc16_modbus(data: Buffer) -> int.

CRC byte order on the wire. Per serial §2.5.1.2: "low-order byte of the field is appended first, followed by the high-order byte." This is opposite to the big-endian convention app §4.2 uses for data fields — easy to mis-implement. The framer's verify_crc and the writer's CRC append must both honor this little-endian-on-wire order. Tested against the worked example from serial §6.2.2 Appendix B.

11. Decoders / encoders for multi-register types

Living in anymodbus.decoders (and surfaced as methods on Slave):

class WordOrder(StrEnum):
    HIGH_LOW = "high_low"      # MSW first — equivalent to struct.pack(">f", ...)
    LOW_HIGH = "low_high"      # LSW first — common on certain controllers

class ByteOrder(StrEnum):
    BIG = "big"                # within each 16-bit word — Modbus spec (App Protocol §4.2)
    LITTLE = "little"          # rare, seen on some devices

class RegisterType(StrEnum):
    INT16 = "int16"; UINT16 = "uint16"
    INT32 = "int32"; UINT32 = "uint32"
    INT64 = "int64"; UINT64 = "uint64"
    FLOAT32 = "float32"; FLOAT64 = "float64"
    STRING = "string"

# Per-type helpers (also exposed on Slave for the common-case helpers):
def decode_float32(words, *, word_order=HIGH_LOW, byte_order=BIG) -> float: ...
def encode_float32(value, *, word_order=..., byte_order=...) -> tuple[int, int]: ...
def decode_float64(...): ...; def encode_float64(...): ...
def decode_int16(...): ...; def encode_int16(...): ...
def decode_int32(...): ...; def encode_int32(...): ...
def decode_int64(...): ...; def encode_int64(...): ...
def decode_string(words, *, byte_order=BIG, encoding="ascii", strip_null=True) -> str: ...
def encode_string(value, *, register_count=None, byte_count=None, byte_order=BIG, ...): ...

# Type-dispatched single entry point — the recommended API for downstream
# device libraries that drive a register schema from configuration:
def decode(words, *, type: RegisterType, word_order=..., byte_order=..., ...) -> int | float | str: ...
def encode(value, *, type: RegisterType, register_count=None, byte_count=None, ...) -> tuple[int, ...]: ...

All four (word_order × byte_order) combinations are covered. Defaults are high-word-first, big-endian within word — equivalent to struct.pack(">f", ...). The Modbus Application Protocol spec (§4.2) defines big-endian byte ordering within a single 16-bit register but does not standardize multi-register word ordering: that's vendor-defined. HIGH_LOW is simply the most common convention. minimalmodbus uses 0..3 magic numbers; we use named enums for clarity at call sites. Downstream device libraries layer their vendor-specific defaults on top by passing the order explicitly.

12. Testing strategy

12.1 Test categories

  • Unit (fast, in-process): PDU codec roundtrips (hypothesis), CRC vector tests against well-known fixtures, framer state-machine tests with a MemoryByteStream fake.
  • Integration: client_slave_pair() — wires Bus to a MockSlave over anyserial.testing.serial_port_pair(). Runs full RTU handshakes including timing.
  • Fault-injection: FaultPlan from anyserial — re-exported and extended with Modbus-aware faults (drop random bytes, flip a CRC bit, hold response for N seconds, return wrong slave address).
  • Hardware (opt-in): pytest -m hardware with ANYMODBUS_TEST_PORT + ANYMODBUS_TEST_SLAVE_ADDRESS env vars, plus a tiny YAML manifest of expected register values for the device under test.
  • Concurrency stress: spawn N tasks all calling slave.read_holding_registers on the same bus, assert all responses correct, no frame fusion. Validates that the bus lock is doing its job under contention.

Spec-derived correctness tests (must-have for v0.1):

  • test_framer_response_length_table — assert each entry in _FIXED_TAIL and _BYTE_COUNT_1B against a spec-derived fixture (one row per FC), so a future code change that mutates the table fails loudly.
  • test_crc_byte_order_low_then_high — feed the worked example from serial §6.2.2 Appendix B through crc16_modbus, assert both the integer value and that the on-wire encoding emits low byte before high byte.
  • test_bus_slave_zero_rejectedbus.slave(0) raises ConfigurationError; the only broadcast surface is Bus.broadcast_*.
  • test_broadcast_methods_only_writes — assert by introspection that Bus.broadcast_* exposes only write methods; no read variants exist.
  • test_broadcast_holds_turnaround_delay — measure that the bus lock is held for ~broadcast_turnaround seconds after a broadcast write, so the next unicast request can't preempt slave processing.
  • test_broadcast_no_rx_attempted — with a MockSlave that records whether anything was read after the request, assert nothing is read after a broadcast.
  • test_unexpected_slave_keeps_waitingMockSlave injects a stray frame addressed to a different slave, then the right one within the same response timeout; assert the right reply is returned and the deadline was not reset.
  • test_unknown_exception_code_returns_unknown_class — feed exception codes 0x07, 0x09, 0xFF and assert ModbusUnknownExceptionError with the raw code preserved.
  • test_known_unsupported_fc_raises_precise_error — feed a forged response with FC 0x07/0x08/0x18/etc. and assert ModbusUnsupportedFunctionError, not FrameError or stream corruption.
  • test_per_fc_quantity_bounds — hypothesis-driven, one parametrize per FC, asserting both min-1 and max+1 raise.
  • test_fc_05_wire_value_enforcement — encoder produces 0xFF00/0x0000 only; decoder rejects any other value with ProtocolError.
  • test_pdu_max_byte_count_sanity — fuzz the rx framer with byte_count in (251..255) and assert FrameError with no large allocation.
  • test_fc_zero_rejected — forged response with FC byte == 0 raises ProtocolError.
  • test_slave_address_validationbus.slave(0), bus.slave(248), bus.slave(-1), bus.slave(256) all raise ConfigurationError; bus.slave(1) and bus.slave(247) succeed.

12.2 MockSlave design

class MockSlave:
    address: int
    coils: bytearray
    discrete_inputs: bytearray
    holding_registers: list[int]
    input_registers: list[int]

    async def serve(self, stream: anyio.abc.ByteStream) -> None:
        """Read requests, write responses, until cancelled."""

def client_slave_pair(*, slave_address: int = 1) -> tuple[Bus, MockSlave]:
    """Returns (bus, slave) pair backed by anyserial's serial_port_pair."""

Expose enough surface that downstream device libraries can spin up a MockSlave preloaded with their device's register map and write protocol-level integration tests without hardware.

13. Performance strategy

Not the primary lever — Modbus RTU is 19200 baud most of the time, hardware-limited. But measure:

  • Round-trip latency vs pymodbus and minimalmodbus on a loopback PTY — target ≤ pymodbus on small reads (single register).
  • Concurrent fan-out across multiple buses (different ports) — target near-linear scaling, the same demonstration anyserial leans on.
  • Single-bus serialization throughput — target maximum FC 3 reads per second on a given baud, characterize headroom over the on-wire ceiling.

Benchmarks live in benchmarks/ under pytest-benchmark. CI doesn't run them, but make bench does.

14. Documentation plan

Built with Zensical (same as anyserial). File list, mirroring anyserial's structure:

docs/
├── index.md
├── quickstart.md              # 30-line example
├── configuration.md           # BusConfig, RetryPolicy, TimingConfig
├── rtu.md                     # 8E1 default, 3.5-char gap, frame structure
├── framing.md                 # Length-aware reader rationale
├── timing.md                  # Per-baud table, RS-485 considerations
├── exceptions.md              # Full hierarchy + Modbus exception code table
├── cancellation.md            # AnyIO scopes, request_timeout precedence
├── decoders.md                # Float/int32/string + word-order matrix
├── capabilities.md            # Probe pattern, SlaveCapabilities
├── sync.md                    # Sync wrapper notes
├── testing.md                 # MockSlave, client_slave_pair, FaultPlan
├── performance.md             # Numbers + how we measure
├── troubleshooting.md         # "no response" → checklist
├── migration-from-pymodbus.md # Address all the pymodbus pain points by example
├── migration-from-minimalmodbus.md
├── design.md                  # Stub include of root DESIGN.md
└── changelog.md               # Stub include of root CHANGELOG.md

migration-from-pymodbus.md is high-leverage — it walks through the live tradeoffs (AnyIO vs asyncio, tx-side 3.5-char timing, idempotent-only retry default, connection-on-sustained-timeout posture, strict typing, required-parity keyword, RTU-client-only scope) with side-by-side code, framed honestly as design choices rather than as bugs in pymodbus. That posture — match pymodbus's §20 audit, don't oversell — is how we earn migrations from a mature incumbent.

15. Tooling & packaging

Mirror anyserial/pyproject.toml. Key bits:

[project]
name = "anymodbus"
dynamic = ["version"]
description = "Async-native Modbus RTU client for Python, built on AnyIO and anyserial."
readme = "README.md"
requires-python = ">=3.13"
license = "MIT"
license-files = ["LICENSE"]
keywords = ["modbus", "modbus-rtu", "rs485", "industrial", "scada", "async", "anyio", "serial"]
classifiers = [
    "Development Status :: 3 - Alpha",
    "Framework :: AnyIO",
    "Intended Audience :: Developers",
    "Intended Audience :: Manufacturing",
    "License :: OSI Approved :: MIT License",
    "Operating System :: OS Independent",
    "Programming Language :: Python :: 3.13",
    "Programming Language :: Python :: 3.14",
    "Programming Language :: Python :: Implementation :: CPython",
    "Topic :: System :: Hardware",
    "Topic :: Communications",
    "Typing :: Typed",
]
dependencies = [
    "anyio>=4.13",
    "anyserial>=0.1.1",
]

[project.optional-dependencies]
trio = ["trio>=0.27"]

[dependency-groups]
dev    = [{include-group="lint"}, {include-group="type"}, {include-group="test"}, {include-group="docs"}, "pre-commit>=4.0"]
lint   = ["ruff>=0.8"]
type   = ["mypy>=1.13", "pyright>=1.1.390"]
test   = ["pytest>=8.3", "pytest-cov>=6.0", "coverage[toml]>=7.13.5", "hypothesis>=6.120", "trio>=0.27"]
bench  = ["pytest-benchmark>=4.0"]
docs   = ["zensical>=0.0.33"]
  • Same Ruff rule set as anyserial. Add T20 (no print) for examples discipline.
  • mypy strict + pyright strict (dual checker).
  • pytest filterwarnings = ["error", "ignore::DeprecationWarning:anyio.*"].
  • Markers: hardware, slow, concurrency. Hardware deselected by default.
  • hatch-vcs for version → src/anymodbus/_version.py.
  • Makefile mirroring anyserial's targets (help/install/sync/lint/format/typecheck/test/test-all/cov/bench/docs/clean + act-*).

16. CI/CD plan

.github/workflows/:

  • ci.yml — lint, typecheck (mypy + pyright), unit tests on {ubuntu, macos, windows} × {3.13, 3.14}, integration tests on Linux (uses anyserial's serial_port_pair which works under Linux PTYs), free-threaded 3.13t allowed-failure, build (uv build + twine check).
  • bench.yml — manual dispatch only.
  • docs.yml — Zensical build + GH Pages deploy.
  • publish.yml — PyPI publish on tag, trusted publisher (OIDC).

Top-level permissions: contents: read. Concurrency-cancel-in-progress per ref. UV_FROZEN: "1". astral-sh/setup-uv@v8. Codecov upload per job, flagged.

17. Repository skeleton

anymodbus/
├── .github/workflows/{ci,bench,docs,publish}.yml
├── src/anymodbus/...
├── tests/
│   ├── unit/
│   │   ├── test_crc.py
│   │   ├── test_pdu_roundtrip.py        # hypothesis
│   │   ├── test_framer.py
│   │   └── test_decoders.py             # word-order matrix
│   ├── integration/
│   │   ├── test_client_slave_pair.py
│   │   ├── test_concurrent_safety.py    # N tasks share one bus; assert no frame fusion
│   │   ├── test_retry_policy.py
│   │   └── test_fault_injection.py
│   └── hardware/
│       └── test_real_device.py          # opt-in
├── benchmarks/
│   ├── bench_roundtrip.py
│   └── bench_concurrent.py
├── docs/...
├── examples/
│   ├── 01_basic_read.py
│   ├── 02_concurrent_polling.py
│   ├── 03_float_setpoint.py             # 32-bit float read/write across two registers
│   └── 04_with_anyserial_rs485.py
├── DESIGN.md                            # This document
├── CHANGELOG.md
├── README.md
├── LICENSE
├── Makefile
├── pyproject.toml
└── zensical.toml

18. Roadmap

v0.1 — RTU client MVP (target: 2 weeks of focused work)

  • Codecs for FC 0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x0F, 0x10.
  • Bus + Slave + Framer + CRC + length-aware reader.
  • Exception hierarchy + code translator (ConfigurationError separated from ProtocolError).
  • RetryPolicy with idempotent-only default and retry_on filter.
  • Decoders: int16/int32/int64 (signed and unsigned), float32/float64, and string, with WordOrder / ByteOrder enums (most-common-convention defaults). A type-dispatched decode(words, type=RegisterType.X, ...) / encode(value, type=RegisterType.X, ...) pair is the recommended entry point for downstream device libraries that drive a register schema from configuration.
  • Sync wrapper.
  • Broadcast helpers (Bus.broadcast_*) honouring timing.broadcast_turnaround.
  • MockSlave + client_slave_pair + concurrency tests.
  • Migration-from-pymodbus doc with side-by-side examples.
  • Full mypy strict + pyright strict + ruff clean + 90%+ coverage.
  • Published to PyPI.

v0.1 connection contract: if the underlying stream raises anyio.BrokenResourceError, the Bus surfaces ConnectionLostError and the bus is dead — open a new one. There is no auto-reconnect in v0.1 (unlike pymodbus's retries+3-then-reconnect behaviour). A thin ResilientBus wrapper is on the v0.2/v0.3 roadmap.

v0.2 — Hardening & extras

  • FC 0x16 (Mask Write), 0x17 (Read/Write Multiple).
  • Slave.probe() capability detection.
  • FC 0x2B / MEI 0x0E (Read Device Identification). Per app §6.21, multi-object responses use a More Follows / NextObjectId continuation loop — a single user call may issue 1..N transactions on the bus. Wrapper API:
    await slave.read_device_identification(
        category: Literal["basic", "regular", "extended"] = "basic",
    ) -> dict[int, bytes]   # ObjectId -> raw object value
    await slave.read_device_identification_object(object_id: int) -> bytes  # individual access (ReadDevId code 0x04)
    
    The streaming form loops until the response's More Follows byte is 0x00, advancing Object Id to the server's Next Object Id each iteration. Each segment is independently retried under the active RetryPolicy; on partial-segment failure the partial dict is attached to the raised ModbusError for diagnostics. Individual-access form is a single transaction.
  • Benchmarks vs pymodbus / minimalmodbus published in docs/performance.md.
  • More fault-injection scenarios.

v0.3 — Modbus TCP

  • anymodbus.tcp adds open_modbus_tcp(host, port) returning a Bus over an anyio.connect_tcp stream.
  • MBAP framer (different framing — adds transaction ID, no CRC). Cleanly slot in as an alternative Framer strategy without disturbing the Bus API.

v0.4 — Modbus ASCII (optional, only if a user asks)

v1.0 — API freeze

Lock the public surface. Anything user-visible after this needs a deprecation cycle with warnings.deprecated.

19. Open questions to flag

  1. Default parity / baudrate. Resolved: open_modbus_rtu requires both as keyword arguments with no default. Real-device defaults vary too widely (8N1 vs 8E1, 9600 vs 19200 vs 38400 ...) for any portable default to be safe. Force the user to make a deliberate choice. Note that serial §2.5.1 makes 8E1 the spec default — when a downstream library has no better information, that's the recommendation to surface in docs.
  2. Broadcast (slave_address=0). Resolved: specified in §6.6. Broadcasts go through Bus.broadcast_* methods. bus.slave(0) raises ConfigurationError. The 3.5-char tx gap is held before the broadcast, and timing.broadcast_turnaround (default 100 ms per serial §2.4.1) is held after, before the bus lock is released. Only write FCs (5, 6, 15, 16) are valid; reads, mask write, and read/write multiple raise ValueError synchronously.
  3. Should Bus accept any anyio.abc.ByteStreamConnectable and own connect/reconnect? Open. Lean: no for v0.1. Caller hands in an already-connected stream. Reconnection is a v0.2+ topic and likely belongs in a thin ResilientBus wrapper.
  4. Inter-character timeout (1.5 char-times). Resolved: specified in §6.1 as TimingConfig.inter_char_idle, used by both the unknown-FC gap-based reader (§6.3) and the unexpected-slave drain logic (§6.3). Default max(1.5 * 11 / baudrate, 0.00075) per serial §2.5.1.1.
  5. Logging. Resolved: use logging with a single named logger anymodbus.bus, log frame hex at DEBUG, exception responses and discarded stray frames at INFO, CRC/timeout at WARNING. Ruff's LOG/G rules already enforce extra-arg style.

20. Honest differentiation from the existing ecosystem

anymodbus is not a drop-in replacement for pymodbus. pymodbus is more mature, broader in scope (TCP/ASCII/server/simulator), and works fine for most users. The differences below are the cases where anymodbus's tradeoffs fit better.

Verified against pymodbus 3.13.0 (latest stable) and 4.0.0dev10

Concern pymodbus current anymodbus
AnyIO-native (asyncio + uvloop + trio) No — asyncio only (import asyncio throughout transaction/transport) Yes
Concurrency lock on bus transactions asyncio.Lock (in TransactionManager.execute) anyio.Lock
Length-aware rx framer Yes — pdu_class.calculateRtuFrameSize() Yes
Tx-side enforced 3.5-char inter-frame gap Not enforced (lock alone, no pre-tx sleep) Enforced
Idempotent-only retry default No — single retries: int for all FCs Yes (retry_idempotent_only=True by default)
Connection on sustained timeout Closes after retries+3 (auto-reconnects if configured) Raises only; no connection effect
Required parity keyword No — defaults to "N" Yes (no default; opinionated correctness)
mypy strict = true No (partial-strict flags) Yes
pyright typeCheckingMode standard strict
Scope Client + server, RTU + TCP + ASCII + UDP + TLS + simulator RTU client only

Things pymodbus is better at today

  • Battle-tested across many years and many devices. anymodbus is pre-alpha.
  • Auto-reconnect behavior built in. We require the caller to manage the connection.
  • Broader scope — if you need TCP, ASCII, or a server, pymodbus is the answer.
  • Mature error recovery for flaky industrial hardware.

versus minimalmodbus

minimalmodbus is sync-only, pyserial-coupled, and a single 3000-line file. Its strengths are simplicity and an ergonomic per-instrument API. We borrow the per-slave-handle ergonomic. If you're writing a sync bench script and never need async, minimalmodbus is a perfectly good choice.

versus umodbus / async-modbus

umodbus (AdvancedClimateSystems) is a low-level codec-only library; async-modbus is a thin async wrapper that pairs umodbus with serialio/sockio. Both have small ecosystems. We share their "PDU codec is pure functions, transport is pluggable" architecture but ship a complete client.


Sources informing this plan

  • The Modbus Application Protocol spec v1.1b3 and the Modbus over Serial Line spec v1.02 — the canonical references for framing, timing, function codes, and exception codes.
  • Direct reading of pymodbus 3.13.0 (latest stable) and 4.0.0dev10 source — pymodbus/transaction/transaction.py, pymodbus/framer/rtu.py, pymodbus/client/serial.py — to ground the comparison in §20 against current behavior rather than historical bug reports.
  • minimalmodbus for the per-instrument ergonomic, and uModbus for the "pure-codec ⊕ pluggable transport" architecture.
  • Linux RS-485 kernel docs for the kernel-vs-userspace direction-control story.
  • anyserial's own DESIGN.md and pyproject.toml as the conventions reference.